Configure the Alarms

Command: CL (Configure aLarms). The HSM must be in the Secure state.

Function:     To enable or disable the motion alarm and temperature alarm. The HSM alarm circuitry typically need to be turned off if the HSM is to be moved. The alarms should be turned on while the HSM is in service. The alarm settings can optionally be saved to a Smartcard.

Inputs:        Temperature alarm status: N or F.
Motion alarm status: N or F.
Save settings to Smartcard: Y or N.

Outputs:     None.

Errors:        Card not formatted to save/retrieve HSM settings.
Attempt with another card? [Y/N]:

Example:

Secure> CL <Return>

LMKs must be erased before proceeding.

Erase LMKs? [Y/N]: Y <Return>

Temperature Alarm [oN/ofF]: F <Return>
Motion Alarm [oN/ofF]: F <Return>
Save ALARM settings to smart card? [Y/N]: Y <Return>

Insert card and press ENTER: <Return>

ALARM settings saved to the smart card.